Heart Plus Aed
$64.64
$101.48
Description Reviews HeartPlus NT-180 is a compact, portable device that analyses the heart’s rhythm and delivers a defibrillation shock to re-establish the normal heart rhythm. HeartPlus NT -180 guides the user through each step of the defibrillation process by providing voice/ visual prompts.HeartPlus NT -180 of Nanoomtech Co., Ltd provides Uni-Pads which can be used for both adults and child and two types of cartridges, integrated-type or separated-type.TECHNICAL DETAILS:Energy : 180J(Adult), 50J(Child)Shock Charge Time : Approx. 13 SecondsLead 2Analysis Time : Less than 11 SeconsECG 1,000 instance of 5 seconds recordings Ambient Noise : Total 60 Minutes (4 instances of 15 minute cycles)Self-Test: Times & Result of 3,000 eventsProduct HighlightsDefibrillatorDefibrillator SeriesHeartPlus NT-180Set ConfigurationDefibrillator, battery pack, sealed electrode pads, HeartPlus User Guide, Protective Carrying Case, “NT-MPR” CD-ROM USB cableWaveformTruncated Exponential BiphasicEnergy180J (adult, impedance 50?) / 50J (pediatric, impedance 50?)ShockChargelimeILess than 13 secondsShock MethodManual button (flashes when ready)Mode ConversionAdult/Child separate power buttons Child Mode delivers 50J Pediatric shock for patients weighing less than 25kg, approximately 12 months to 8 years old)PhysicalDimensions7.1cm (H) x29.3cm (W) x29.1cm (D)Weight1.9kg (including battery pack and electrode pad)EnvironmentaWater resistanceIPX2 based on IEC 60529TemperatureOperating : 0? to 40? / Storage : -20? to 60?Humidity(operating/storage)10% to 95% Relative Humidity, Non-CondensingAltitude(operating/storage)0 to 2000 metersDrop test1MECGECG RecordLEAD IIAnalysis OverviewPatient evaluated to determine whether ECG rhythm represents shockable or non-shockable state. Shockable rhythms are ventricular fibrillation (VF) and ventricular tachycardia (VT).Analysis timeLess than 11 seconds (Read: 5 seconds ± 2 seconds, Analyze: within 4 seconds)Audio/ Visual instructionAfter device is powered on, step-by-step voice instructions guide first responder through resuscitation procedure, which includes pads placement, hands offtimes (analysis and shock process), and CPRCPR instruction prompts user to commence cardiopulmonary resuscitation, while flashing metronome light sets pace at 100 compressions per minute for 30 compressions with brief pause for 2 mouth-to-mouth breaths (5 repetitions), in accordance with American Heart Association 2010 guidelines.DataStoreda dataECG recordings, operation information (whether shock delivered or not), ambient noise, self-diagnostics historyMemory capacityECG: 1,000 instances of 5 seconds recordings AmbientNoise: Total 60 minutes (4 instances of 15 minute cycles)Self-Test: Times & results of 3,000 eventsStorage typeInternal MemoryAccess/search“NT-MPR” App (for PC) via USB connectionself-diagnostics TestDaily self-diagnostics tests ensure that circuits for measuring patient impedance, control circuit internal discharge of electric energy, and control circuit for charge/discharge of electric energy are functioningA voice prompt stating “Equipment check is needed” continuously in the event self-diagnostics check fails.Upon completion of daily self-diagnostics test, results are automatically stored within device’s internal memory.Battery CheckWhen battery reserve is at acceptable level to provide sufficient electric charges and there are no problems with circuitry detected during self check, there Status LEDs above the power button blink in order from left to right during self check.All three Status LEDs blink at the same time continuously with low or critical battery voice prompts when battery is at low or critical levels (low: shock possible, critical: shock not possible).Battery Status Audible WarningsLow: Voice prompt states “Battery’s voltage is low, check battery”Critical: Voice prompt states “Change cartridge”Electrode padsShelf LifeTwo (2) years, for one-time use onlyConductive GelPE foam, HydrogelConductive ElementAgCl (Silver Chloride)Cable Length2.1m ( 1%)Applicable AgesAll ages (12 months & older)SealingAirtightSize125mm x 95mmPads PlacementAnterior-lateral (visual details on pads)Battery CartridgeTypeNon-rechargeable lithium (LiMn02)Capacity180 shocks @ 25? ,130 shocks @ 0?VoltageDC 21V& DC V / 1,400mAHStandby Mode LifeRecommended five (5) years @ 25?Dimensions3.3cm (H) x 15.0cm (W) x 11.0cm (D) Be the first to write your review!
Defibrillator